| Design: |
Free standing unit with integrated cart,
motorized Z axis, auto focus, X-Y beam positioning system, self-aligning
spring loaded sealed bearings, stationary processing table, Quick Change
Laser Cartridge™ compatibility, protected optical path, interchangeable
focusing optics, flash upgradable electronics, job complete indicator,
system status indicator, relocatable origin, enhanced vector cutting and
rubber stamp mode. |
| Laser Compatibility: |
UL-25, -30, -35, -40, -45,
-50 or -60
watt air-cooled, RF driven, sealed CO2 laser in the
pre-aligned Quick Change Cartridge™. |
| Focusing Optic: |
Standard 2.0" (50mm) focal length lens in
enclosed lens cartridge; optional lenses available. |
| Power Control: |
Digital power control continuously variable
from 0-100%, automatic proportional pulsing and color linked power
settings. |
| Resolution: |
1000 x 1000 DPI, 500 x 500 DPI, 333 x 333 DPI,
250 x 250 DPI, 200 x 200 DPI and low resolution draft mode; choice of
error diffusion or half toning for grayscale images. |
| Work Area: |
24" x 18" (609 x 457mm) |
| Table Size: |
29" x 23" (736 x 584mm) |
| Max. Part Size: |
29" wide by 23" deep x 9" thick
(736 x 584 x 228mm). |
| Computer Interface: |
Parallel and serial printer port; compatible
with Windows XP, 2000, NT, ME, 98, 95, and HPGL. |
| Memory Buffer: |
Intelligent buffer with automatic data
compression stores up to 99 files with all settings; files are addressable
and repeatable in any order and may be deleted after completion to free
memory; buffer can be switched to single file mode. |
| Display Panel: |
LCD display shows current file name, laser
power, engraving speed, run time, files loaded into memory buffer, setup
and diagnostic menus. |
| Operating Modes: |
Optimized landscape or portrait mode with
raster or vector engraving, vector cutting or combined vector/raster
processes. |
| Dimensions: |
38" high x 36" wide x 36.5"
deep (965 x 914 x 927mm). |
| Weight: |
Approximately 250 pounds (113kg). |
| Safety: |
Class IIIa interlocked safety enclosure.
|
| |
Facility Requirements
|
| Electrical: |
Single phase 110 VAC, 15 amp, 50/60 Hz. Single
phase 220 VAC, 8 amp, 50/60 Hz. |
| Exhaust: |
Outside exhaust required. One 4" (102mm)
connection requiring 250 CFM air flow at 6 inches of water (425m3/hr
at 1.5kPa). |
|
Cooling:
|
Air-cooled, ambient operating range of 50°-95°F
(10°F-35°C)
|
|